North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
24 Kailua Avenue Budgewoi NSW 2262
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to a 2,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 71 against 70 for energy and 41 against 40 for water.
Key features
- Windows
- Up to aluminium frames 45.3 m², single glazing 14.6 m², double glazing 30.7 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Gas instantaneous with a performance of 5 stars
- Air conditioning and heating
- 1-phase airconditioning, non ducted (living area and bedroom)
Built by Chiselwood Homes.
BASIX certificate
- Energy score
- 71 (target 70)
- Water score
- 41 (target 40)
- Thermal performance
- Pass
- Materials score
- -26
- Heating load
- 21 MJ/m² a year
- Cooling load
- 29 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 141.1 m²
- Unconditioned floor area
- 20.6 m²
- Site area
- 556 m²
- Roof area
- 181 m²
- Garden area
- 364 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Gas instantaneous with a performance of 5 stars
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 45.3 m², single glazing 14.6 m², double glazing 30.7 m²
Heating
- Living area: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (polystyrene)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (no added insulation)
- Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1749388S_02, issued 12 November 2024, from the council's DA documents.
Is this your home? Ask us to remove these details.