North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
24 Del Mar Drive Copacabana NSW 2251
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to a 2,000 litre rainwater tank. It beat its BASIX energy target, scoring 71 against 70.
Key features
- Windows
- Up to aluminium frames 59.8 m², single glazing 8.1 m², double glazing 51.8 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 71 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -42
- Heating load
- 35 MJ/m² a year
- Cooling load
- 16 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 215.7 m²
- Unconditioned floor area
- 21 m²
- Site area
- 509 m²
- Roof area
- 156 m²
- Garden area
- 40 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 59.8 m², single glazing 8.1 m², double glazing 51.8 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: suspended floor above enclosed subfloor, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above open subfloor, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1832708S_02, issued 20 February 2026, from the council's DA documents.
Is this your home? Ask us to remove these details.