164 Del Monte Place Copacabana NSW 2251
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to a 2,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 71 against 70 for energy and 41 against 40 for water.
Key features
- Windows
- Up to aluminium frames 55.5 m², timber frames 2.8 m², single glazing 37.4 m², double glazing 20.9 m²
- Wall insulation
- Fibreglass batts or roll; No added insulation
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket; Ceiling: none; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 71 (target 70)
- Water score
- 41 (target 40)
- Thermal performance
- Pass
- Materials score
- -62
- Heating load
- 28 MJ/m² a year
- Cooling load
- 23 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 215.1 m²
- Unconditioned floor area
- 19.6 m²
- Site area
- 567 m²
- Roof area
- 280 m²
- Garden area
- 244 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 55.5 m², timber frames 2.8 m², single glazing 37.4 m², double glazing 20.9 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: cavity brick; frame: timber - H2 treated softwood (no added insulation)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: cavity brick; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: none; roof: foil backed blanket.)
Certificate 1825954S, issued 10 December 2025, from the council's DA documents.