North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
16 Ashwood Close Glenning Valley NSW 2261
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to a 3,000 litre rainwater tank. It beat its BASIX water target, scoring 46 against 40.
Key features
- Windows
- Up to aluminium frames 21.4 m², single glazing 12.6 m², double glazing 8.8 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 67 (target 67)
- Water score
- 46 (target 40)
- Thermal performance
- Pass
- Materials score
- 22
- Heating load
- 20 MJ/m² a year
- Cooling load
- 30 MJ/m² a year
- Bedrooms
- 2
- Conditioned floor area
- 53.8 m²
- Unconditioned floor area
- 6 m²
- Site area
- 1,026 m²
- Roof area
- 91 m²
- Garden area
- 50 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 21.4 m², single glazing 12.6 m², double glazing 8.8 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1781936S, issued 3 February 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.