North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
12A Melbourne Street East Gosford NSW 2250
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 6 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 100 against 70 for energy and 50 against 40 for water.
Key features
- Windows
- Up to aluminium frames 46.8 m², double glazing 46.8 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric boosted solar
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Rustic Touch.
BASIX certificate
- Energy score
- 100 (target 70)
- Water score
- 50 (target 40)
- Thermal performance
- Pass
- Materials score
- -34
- Heating load
- 36 MJ/m² a year
- Cooling load
- 14 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 162.4 m²
- Unconditioned floor area
- 10 m²
- Site area
- 491 m²
- Roof area
- 253 m²
- Garden area
- 130 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric boosted solar
- Solar panels
- 6 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 46.8 m², double glazing 46.8 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (polystyrene)
- Floor: suspended floor above open subfloor, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (not specified)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1794549S, issued 8 May 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.