North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
12 Beaufort Road Terrigal NSW 2260
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 5 kW of solar panels and a 5,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 89 against 70 for energy and 43 against 40 for water.
Key features
- Windows
- Up to aluminium frames 82.2 m², single glazing 28.4 m², double glazing 53.8 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by T & W Building.
BASIX certificate
- Energy score
- 89 (target 70)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Materials score
- -35
- Heating load
- 28 MJ/m² a year
- Cooling load
- 22 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 259.9 m²
- Unconditioned floor area
- 41 m²
- Site area
- 943 m²
- Roof area
- 345 m²
- Garden area
- 250 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric heat pump
- Solar panels
- 5 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 82.2 m², single glazing 28.4 m², double glazing 53.8 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (polystyrene)
- Floor: suspended floor above enclosed subfloor, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above open subfloor, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1780353S, issued 20 January 2025, from the council's DA documents.