BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 2 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 88 against 70 for energy and 41 against 40 for water.

Key features

Windows
22 windows and glazed doors: Trend Al Hinged Door SG 4Clr T; Trend ThermaRes Thermally Broken Fixed Window; Trend ThermaRes Thermally Broken Sliding Window and 2 more types
Wall insulation
Fibreglass batts or roll
Roof and ceiling insulation
Roof Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 1.30, medium colour
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Perry Homes.

BASIX certificate

Energy score
88 (target 70)
Water score
41 (target 40)
Thermal performance
Pass
Materials score
-40
Heating load
23 MJ/m² a year
Cooling load
27 MJ/m² a year
Bedrooms
4
Conditioned floor area
178.4 m²
Unconditioned floor area
10.6 m²
Site area
540 m²
Roof area
200 m²
Garden area
150 m²
Climate zone
NatHERS climate zone 15
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Solar panels
2 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 40 m², single glazing 40 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1773148S, issued 15 November 2024, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
Hero 4.1
Rated on
04 Oct 2024
Living room glazing by direction
ENE 16.7 m², WSW 12.8 m², NW 4.3 m², NNW 9 m²
All glazing by direction
ENE 23.9 m², SSE 19.7 m², WSW 19.8 m², NW 4.3 m², NNW 31.9 m²

Roof

  • Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 1.30, medium colour
  • FLAT-01: Flat Framed / Skillion Metal Roof & Flat PB Ceiling 1.30, medium colour

Window types

  • TND-021-01 A Trend Al Hinged Door SG 4Clr T: U-value 6.03, SHGC 0.61
  • TND-100-026 Trend ThermaRes Thermally Broken Fixed Window: U-value 1.9, SHGC 0.3
  • TND-104-015 Trend ThermaRes Thermally Broken Sliding Window: U-value 2.25, SHGC 0.34
  • TND-108-017 Trend ThermaRes Thermally Broken Sliding Door: U-value 1.89, SHGC 0.34
  • TND-115-025 Trend ThermaArc Thermally Broken INLINE Awning Window: U-value 2.15, SHGC 0.27

Window schedule

  • Bathroom, window TND-115-025: 2,100 × 600 mm facing SSE
  • Bedroom 01, window TND-108-017: 2,400 × 3,579 mm facing SSE
  • Bedroom 01, window TND-115-025: 2,400 × 3,600 mm facing NNW
  • Bedroom 02, window TND-104-015: 1,500 × 2,400 mm facing SSE
  • Bedroom 03, window TND-104-015: 1,500 × 2,400 mm facing ENE
  • Bedroom 04, window TND-104-015: 1,500 × 2,400 mm facing ENE
  • Ensuite, window TND-115-025: 2,400 × 900 mm facing SSE
  • Ensuite, window TND-115-025: 2,400 × 900 mm facing SSE
  • Ensuite, window TND-104-015: 1,800 × 2,700 mm facing WSW
  • Garage, window TND-021-01 A: 2,400 × 820 mm facing SSE
  • Hallway, window TND-108-017: 2,400 × 2,679 mm facing NNW
  • Hallway, window TND-115-025: 2,400 × 1,800 mm facing NNW
  • Kitchen/Living, window TND-115-025: 2,400 × 600 mm facing NNW
  • Kitchen/Living, window TND-021-01 A: 2,400 × 1,200 mm facing NNW
  • Kitchen/Living, window TND-100-026: 2,400 × 1,500 mm facing NNW
  • Kitchen/Living, window TND-115-025: 411 × 2,700 mm facing NNW
  • Kitchen/Living, window TND-108-017: 2,400 × 4,248 mm facing ENE
  • Kitchen/Living, window TND-115-025: 2,400 × 2,700 mm facing ENE
  • Kitchen/Living, window TND-108-017: 2,400 × 5,328 mm facing WSW
  • Laundry, window TND-115-025: 2,400 × 900 mm facing WSW
  • Laundry, window TND-108-017: 2,400 × 1,450 mm facing NNW
  • Living 1, window TND-115-025: 2,400 × 1,800 mm facing NW

Certificate HR-RSB43G-05, issued 4 October 2024, from the council's DA documents. Verify this certificate