North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
1 Samantha Crescent Kincumber NSW 2251
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 5 kW of solar panels and a 5,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 94 against 70 for energy and 53 against 40 for water.
Key features
- Windows
- Up to aluminium frames 53.6 m², single glazing 16.9 m², double glazing 36.7 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 21 to 25 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 94 (target 70)
- Water score
- 53 (target 40)
- Thermal performance
- Pass
- Materials score
- -21
- Heating load
- 29 MJ/m² a year
- Cooling load
- 22 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 187.9 m²
- Unconditioned floor area
- 10.6 m²
- Site area
- 627 m²
- Roof area
- 250 m²
- Garden area
- 68 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric heat pump with a performance of 21 to 25 STCs or better
- Solar panels
- 5 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 53.6 m², single glazing 16.9 m², double glazing 36.7 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (not specified)
- Garage floor: concrete slab on ground (not specified)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1767883S, issued 9 October 2024, from the council's DA documents.