North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
8/-/DP271605
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to a 5,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 71 against 68 for energy and 56 against 40 for water.
Key features
- Windows
- Up to aluminium frames 71.3 m², single glazing 8.6 m², double glazing 62.7 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: not specified
- Hot water
- Electric heat pump
- Air conditioning and heating
- 1-phase airconditioning, non ducted (living area and bedroom)
BASIX certificate
- Energy score
- 71 (target 68)
- Water score
- 56 (target 40)
- Materials score
- -20
- Heating load
- 9 MJ/m² a year
- Cooling load
- 53 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 125.1 m²
- Unconditioned floor area
- 61.4 m²
- Site area
- 400,000 m²
- Roof area
- 238 m²
- Garden area
- 100 m²
- Climate zone
- NatHERS climate zone 10
- Hot water
- Electric heat pump
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 71.3 m², single glazing 8.6 m², double glazing 62.7 m²
Heating
- Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: suspended floor above enclosed subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: not specified.)
Certificate 1850865S, issued 11 June 2026, from the council's DA documents.
Is this your home? Ask us to remove these details.