Skip to main content

31 Riverside Drive Mullumbimby NSW 2482

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 6.4 stars out of 10. Its BASIX certificate commits it to a 6,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 70 against 65 for energy and 41 against 40 for water.

Key features

Windows
10 windows and glazed doors
Wall insulation
All external walls fibreglass batts or roll
Roof and ceiling insulation
Roof Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 1.30, medium colour
Hot water
Electric heat pump
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
70 (target 65)
Water score
41 (target 40)
Thermal performance
Pass
Materials score
18
Heating load
14 MJ/m² a year
Cooling load
35 MJ/m² a year
Bedrooms
2
Conditioned floor area
85.8 m²
Unconditioned floor area
7.3 m²
Site area
1,111 m²
Roof area
149 m²
Garden area
500 m²
Climate zone
NatHERS climate zone 10
Hot water
Electric heat pump
Rainwater tank
6,000 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 28.4 m², single glazing 28.4 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (hot zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (hot zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (hot zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (hot zone)

Construction and insulation

  • Floor: suspended floor above open subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1826056S_02, issued 4 February 2026, from the council's DA documents.

NatHERS certificate

Star rating
6.4 stars
Rated with
Hero 4.1
Rated on
04 Feb 2026
Living room glazing by direction
N 14.6 m², S 3.6 m²
All glazing by direction
N 19.7 m², E 3.2 m², S 5.4 m²

Roof

  • Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 1.30, medium colour
  • FLAT-02: Flat Framed / Skillion Metal Roof & Cathedral PB Ceiling (11°-33°) 1.30, medium colour

Window schedule

  • Bath HAAWS-070-062 W05-1: 700 × 750 mm facing N
  • Bath HAFWS-065-077 W05-2: 700 × 750 mm facing N
  • Bed 01 HAFWS-065-077 W04-A: 1,400 × 1,440 mm facing N
  • Bed 02 HAFWS-065-077 W06-B: 1,400 × 1,440 mm facing N
  • Bed 02 HASWS-065-077 W07: 700 × 1,800 mm facing E
  • Kitchen/Living/Dining HADWS-065-077 W02: 1,500 × 1,200 mm facing S
  • Kitchen/Living/Dining HALWS-065-045 W10: 2,400 × 750 mm facing S
  • Kitchen/Living/Dining HASDS-045-062 W03: 2,400 × 6,078 mm facing N
  • Laundry HAHDS-065-062 W08: 2,400 × 820 mm facing E
  • Passage HALWS-065-045 W09: 2,400 × 750 mm facing S

Certificate HR-JKHXYO-02, issued 4 February 2026, from the council's DA documents. Verify this certificate