North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
286 Main Arm Road Main Arm NSW 2482
Finding the block on the map…
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 6,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 71 against 68 for energy and 56 against 40 for water.
Key features
- Windows
- 32 windows and glazed doors: Altair Louvre Comp in a timber frame; Cedar Fixed Window - Double Glazed; SoundMizer Timber Sliding Door SEC 100mm 5.00 and 2 more types
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Roof Added insulation absorptance Roof Colour FLAT-02: Flat Framed / Skillion Metal Roof & Cathedral PB Ceiling (11°-33°) 1.30, medium colour
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area)
BASIX certificate
- Energy score
- 71 (target 68)
- Water score
- 56 (target 40)
- Thermal performance
- Pass
- Materials score
- 9
- Heating load
- 9 MJ/m² a year
- Cooling load
- 35 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 130 m²
- Unconditioned floor area
- 14.5 m²
- Site area
- 20,500 m²
- Roof area
- 150 m²
- Garden area
- 100 m²
- Climate zone
- NatHERS climate zone 10
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Rainwater tank
- 6,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- timber frames 142 m², single glazing 20 m², double glazing 122 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (polystyrene)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1813978S, issued 22 September 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- Hero 4.1
- Rated on
- 22 Sep 2025
- Living room glazing by direction
- ENE 19.8 m², SSE 7.2 m², WSW 19.8 m², NNW 28.1 m²
- All glazing by direction
- ENE 49.7 m², SSE 28.5 m², WSW 39.7 m², NNW 29 m²
Roof
- Added insulation absorptance Roof Colour FLAT-02: Flat Framed / Skillion Metal Roof & Cathedral PB Ceiling (11°-33°) 1.30, medium colour
Window types
- BRZ-005-001 Altair Louvre Comp in a timber frame: U-value 4.9, SHGC 0.58
- STG-118-001 Cedar Fixed Window - Double Glazed: U-value 2.9, SHGC 0.63
- TND-040-01 W SoundMizer Timber Sliding Door SEC 100mm 5.00: U-value 2.1, SHGC 0.59
- TND-201-001 Cedar Awning Window: U-value 4.4, SHGC 0.55
- TND-212-001 Cedar Hinged Door: U-value 2.4, SHGC 0.46
Window schedule
- Bathroom, window TND-201-001: 300 × 3,000 mm facing NNW
- Bedroom 1, window STG-118-001: 950 × 4,200 mm facing ENE
- Bedroom 1, window STG-118-001: 950 × 4,200 mm facing SSE
- Bedroom 1: 2,400 × 4,192 mm facing SSE
- Bedroom 1: 2,400 × 4,200 mm facing ENE
- Bedroom 2, window STG-118-001: 950 × 1,000 mm facing WSW
- Bedroom 2, window BRZ-005-001: 2,400 × 1,000 mm facing WSW
- Bedroom 3, window STG-118-001: 950 × 1,000 mm facing WSW
- Bedroom 3, window BRZ-005-001: 2,400 × 1,000 mm facing WSW
- Ensuite, window TND-201-001: 2,400 × 1,000 mm facing SSE
- Ensuite, window TND-201-001: 2,400 × 1,000 mm facing SSE
- Hallway 1: 2,400 × 4,800 mm facing WSW
- Hallway 2: 2,400 × 4,800 mm facing ENE
- Hallway 2, window TND-212-001: 2,040 × 820 mm facing WSW
- Hallway 2, window BRZ-005-001: 2,400 × 1,000 mm facing SSE
- Kitchen/Living, window BRZ-005-001: 2,400 × 1,000 mm facing WSW
- Kitchen/Living, window STG-118-001: 2,400 × 3,000 mm facing SSE
- Kitchen/Living, window BRZ-005-001: 2,400 × 1,000 mm facing ENE
- Kitchen/Living, window STG-118-001: 950 × 4,200 mm facing WSW
- Kitchen/Living, window STG-118-001: 950 × 1,000 mm facing WSW
- Kitchen/Living, window STG-118-001: 950 × 4,200 mm facing NNW
- Kitchen/Living, window STG-118-001: 950 × 4,200 mm facing NNW
- Kitchen/Living, window STG-118-001: 950 × 4,200 mm facing ENE
- Kitchen/Living, window STG-118-001: 950 × 1,000 mm facing ENE
- Kitchen/Living: 2,400 × 4,200 mm facing ENE
- Kitchen/Living, window BRZ-005-001: 2,400 × 1,000 mm facing ENE
- Kitchen/Living: 2,400 × 4,200 mm facing NNW
- Kitchen/Living: 2,400 × 4,200 mm facing NNW
- Kitchen/Living: 2,400 × 4,200 mm facing WSW
- Kitchen/Living, window BRZ-005-001: 2,400 × 1,000 mm facing WSW
- Laundry, window TND-212-001: 2,040 × 920 mm facing ENE
- Laundry Drying Room, window TND-201-001: 2,400 × 1,000 mm facing ENE
Certificate HR-TFPUYG-01, issued 22 September 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.