North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
17 Pacific Esplanade South Golden Beach NSW 2483
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to a 2,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 71 against 68 for energy and 41 against 40 for water.
Key features
- Windows
- Up to aluminium frames 49.9 m², timber frames 27.3 m², double glazing 77.3 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 71 (target 68)
- Water score
- 41 (target 40)
- Thermal performance
- Pass
- Materials score
- -29
- Heating load
- 15 MJ/m² a year
- Cooling load
- 33 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 135 m²
- Unconditioned floor area
- 4.9 m²
- Site area
- 607 m²
- Roof area
- 303 m²
- Garden area
- 250 m²
- Climate zone
- NatHERS climate zone 10
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Induction
- Maximum glazing
- aluminium frames 49.9 m², timber frames 27.3 m², double glazing 77.3 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: suspended floor above enclosed subfloor, hard wood; frame: timber - H2 treated softwood (foil-foam composite board+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1783627S, issued 14 February 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.