BASIX certificate and NatHERS rating

This home has a NatHERS rating of 6.5 stars out of 10. Its BASIX certificate commits it to 2.5 kW of solar panels and a 40,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 89 against 68 for energy and 41 against 40 for water.

Key features

Windows
32 windows and glazed doors: Al Thermally Broken B DG Argon Fill Clear-Clear; Al Thermally Broken A DG Argon Fill Clear-Clear; Al Thermally Broken B DG Air Fill Clear-Clear and 1 more types
Wall insulation
R4, R2.7
Roof and ceiling insulation
Ceiling R5, R4, roof Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour
Hot water
Electric boosted solar with a performance of 26 to 30 STCs or better
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

BASIX certificate

Energy score
89 (target 68)
Water score
41 (target 40)
Thermal performance
Pass
Materials score
-80
Heating load
12 MJ/m² a year
Cooling load
36 MJ/m² a year
Bedrooms
4
Conditioned floor area
269.5 m²
Unconditioned floor area
17 m²
Site area
20,000 m²
Roof area
385 m²
Garden area
62 m²
Climate zone
NatHERS climate zone 10
Hot water
Electric boosted solar with a performance of 26 to 30 STCs or better
Solar panels
2.5 kW
Rainwater tank
40,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Induction
Maximum glazing
aluminium frames 154.9 m², single glazing 27.6 m², double glazing 127.3 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (polystyrene)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (polystyrene)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1790447S, issued 4 April 2025, from the council's DA documents.

NatHERS certificate

Star rating
6.5 stars
Rated with
BERS Pro v5.2.4 (3.23)
Rated on
04 Apr 2025
Wall insulation
R4, R2.7
Ceiling insulation
R5, R4
Floor insulation
R4.0, R2.7, R2.8, R5.0, R1.3, R2.0, R2.5
Living room glazing by direction
N 31.7 m², E 6.4 m², S 17.5 m², W 16.7 m²
All glazing by direction
N 41.1 m², E 19 m², S 20.9 m², W 50.2 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour

Window types

  • ATB-006-01 B Al Thermally Broken B DG Argon Fill Clear-Clear: U-value 3.5, SHGC 0.64
  • ATB-005-01 B Al Thermally Broken A DG Argon Fill Clear-Clear: U-value 3.5, SHGC 0.47
  • ATB-004-01 B Al Thermally Broken B DG Air Fill Clear-Clear: U-value 3.6, SHGC 0.54
  • BRZ-003-001 Aluminium Louvre Window SG 6Clr: U-value 6, SHGC 0.67

Window schedule

  • Kitchen/Living1, window ATB-006-01 B: 2,700 × 9,000 mm facing N
  • Kitchen/Living1, window ATB-006-01 B: 2,700 × 1,693 mm facing N
  • Kitchen/Living1, window BRZ-003-001: 2,700 × 800 mm facing N
  • Kitchen/Living1, window ATB-005-01 B: 1,405 × 1,500 mm facing E
  • Kitchen/Living1, window ATB-006-01 B: 1,405 × 1,500 mm facing E
  • Kitchen/Living1, window BRZ-003-001: 1,405 × 785 mm facing E
  • Kitchen/Living1, window BRZ-003-001: 1,405 × 785 mm facing E
  • Kitchen/Living1, window ATB-006-01 B: 2,700 × 5,325 mm facing S
  • Kitchen/Living1, window ATB-006-01 B: 1,223 × 1,832 mm facing S
  • Kitchen/Living1, window ATB-006-01 B: 828 × 1,072 mm facing S
  • Kitchen/Living1, window ATB-005-01 B: 2,700 × 1,665 mm facing W
  • Kitchen/Living1, window BRZ-003-001: 2,700 × 800 mm facing W
  • Kitchen/Living1, window ATB-006-01 B: 2,700 × 3,720 mm facing W
  • Kitchen/Living1, window ATB-004-01 B: 1,013 × 610 mm facing N
  • entry, window ATB-005-01 B: 3,030 × 1,300 mm facing E
  • entry, window ATB-006-01 B: 2,580 × 2,613 mm facing E
  • entry, window ATB-006-01 B: 2,400 × 1,600 mm facing W
  • entry, window BRZ-003-001: 1,666 × 1,600 mm facing N
  • entry, window ATB-006-01 B: 2,975 × 1,900 mm facing W
  • Laundry, window ATB-006-01 B: 1,405 × 1,500 mm facing N
  • Laundry, window BRZ-003-001: 1,045 × 785 mm facing N
  • Bedroom 2, window BRZ-003-001: 2,363 × 800 mm facing E
  • Bedroom 2, window ATB-006-01 B: 1,200 × 1,200 mm facing S
  • Bedroom 2, window ATB-006-01 B: 2,296 × 2,700 mm facing W
  • bath, window BRZ-003-001: 2,400 × 800 mm facing N
  • Guest, window BRZ-003-001: 2,400 × 800 mm facing W
  • Guest, window ATB-006-01 B: 2,400 × 2,065 mm facing W
  • master n wir, window BRZ-003-001: 2,400 × 800 mm facing S
  • master n wir, window ATB-006-01 B: 2,296 × 2,700 mm facing W
  • master n wir, window BRZ-003-001: 2,400 × 800 mm facing N
  • ensuite, window BRZ-003-001: 2,400 × 800 mm facing W
  • ensuite, window ATB-006-01 B: 2,400 × 1,188 mm facing W

Certificate 0011840626, issued 4 April 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

NatHERS certificate, certificate 0011842457, issued 7 April 2025

NatHERS certificate

Star rating
7.9 stars
Rated with
BERS Pro v5.2.4 (3.23)
Rated on
07 Apr 2025
Wall insulation
R2.5, R5
Ceiling insulation
R5
Floor insulation
R2.5, R5.0, R1.3, R1.5
LED downlights
18
Living room glazing by direction
NE 13.4 m², SE 1.9 m², NW 3.7 m²
All glazing by direction
NE 13.4 m², SE 3 m², SW 4.1 m², NW 3.7 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour

Window types

  • ATB-006-01 B Al Thermally Broken B DG Argon Fill Clear-Clear: U-value 3.5, SHGC 0.64
  • BRZ-003-001 Aluminium Louvre Window SG 6Clr: U-value 6, SHGC 0.67

Window schedule

  • Kitchen/Living1, window ATB-006-01 B: 2,600 × 4,278 mm facing NE
  • Kitchen/Living1, window ATB-006-01 B: 804 × 2,781 mm facing NE
  • Kitchen/Living1, window BRZ-003-001: 2,400 × 785 mm facing SE
  • Kitchen/Living1, window BRZ-003-001: 2,400 × 768 mm facing NW
  • Kitchen/Living1, window ATB-006-01 B: 2,400 × 767 mm facing NW
  • bath, window ATB-006-01 B: 1,405 × 785 mm facing SE
  • Bedroom 1, window ATB-006-01 B: 2,532 × 800 mm facing SW
  • Bedroom 1, window BRZ-003-001: 2,532 × 800 mm facing SW

Certificate 0011842457, issued 7 April 2025, from the council's DA documents. Verify this certificate