Skip to main content

43 Nicholson Street Burwood NSW 2134

Finding the block on the map…

BASIX certificate and NatHERS rating

This home's BASIX certificate commits it to 3 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy target, scoring 82 against 72.

Key features

Windows
Up to aluminium frames 164.1 m², double glazing 164.1 m²
Wall insulation
Fibreglass batts or roll; Foil-foam composite board
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: none
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
82 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
21 MJ/m² a year
Cooling load
8 MJ/m² a year
Bedrooms
6
Conditioned floor area
343 m²
Unconditioned floor area
40.8 m²
Site area
560 m²
Roof area
300 m²
Garden area
125 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
3 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 6 star, kitchen taps 6 star, basin taps 6 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 164.1 m², double glazing 164.1 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (expanding foam)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: timber - untreated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - untreated softwood (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: timber - untreated softwood (no added insulation)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: concrete block/plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
  • External wall: cavity brick; frame: no frame (foil-foam composite board)
  • External garage wall: concrete block/plasterboard; frame: timber - untreated softwood (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: none.)

Certificate 1801807S, issued 27 June 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.