North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
61 Hill Street Broken Hill NSW 2880
BASIX certificate and NatHERS rating
This home beat its BASIX energy and water targets, scoring 73 against 68 for energy and 7 against 0 for water.
Key features
- Windows
- Up to aluminium frames 22.8 m², single glazing 22.8 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: none
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 73 (target 68)
- Water score
- 7 (target 0)
- Materials score
- -34
- Heating load
- 37 MJ/m² a year
- Cooling load
- 24 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 154.8 m²
- Unconditioned floor area
- 39.9 m²
- Site area
- 760 m²
- Roof area
- 280 m²
- Garden area
- 250 m²
- Climate zone
- NatHERS climate zone 46
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 22.8 m², single glazing 22.8 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: AAC veneer; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: none.)
Certificate 1853907S, issued 30 June 2026, from the council's DA documents.
Other certificates for this address
BASIX certificate (alterations and additions), certificate A1855735, issued 12 July 2026
BASIX certificate (alterations and additions)
This BASIX certificate is for alterations and additions, such as an extension or a pool, rather than a whole new house.
- LED lighting
- Yes
Construction and insulation
- Suspended floor above garage: framed (R0.7). R0.50 (down) (or R1.20 including construction) N/A
- Flat ceiling, pitched roof ceiling: R1.95 (up), roof: foil backed blanket (55 mm) medium (solar absorptance 0.475 - 0.70)
Certificate A1855735, issued 12 July 2026, from the council's DA documents.
BASIX certificate, certificate 1852412S, issued 22 June 2026
BASIX certificate
- Energy score
- 69 (target 68)
- Water score
- 2 (target 0)
- Materials score
- 25
- Heating load
- 27 MJ/m² a year
- Cooling load
- 47 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 125.9 m²
- Unconditioned floor area
- 5.9 m²
- Site area
- 602 m²
- Roof area
- 227 m²
- Garden area
- 200 m²
- Climate zone
- NatHERS climate zone 46
- Hot water
- Gas storage with a performance of 4.5 stars
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 27.7 m², single glazing 27.7 m²
Heating
- Living area: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- External wall: framed (metal clad); frame: timber - untreated softwood. all external walls fibreglass batts or roll
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: none.)
Certificate 1852412S, issued 22 June 2026, from the council's DA documents.
BASIX certificate, certificate 1852381S, issued 22 June 2026
BASIX certificate
- Energy score
- 68 (target 68)
- Water score
- 9 (target 0)
- Materials score
- 3
- Heating load
- 43 MJ/m² a year
- Cooling load
- 31 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 151.2 m²
- Unconditioned floor area
- 10.8 m²
- Site area
- 507 m²
- Roof area
- 291 m²
- Garden area
- 186 m²
- Climate zone
- NatHERS climate zone 46
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 26.4 m², double glazing 26.4 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: suspended floor above open subfloor, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1852381S, issued 22 June 2026, from the council's DA documents.
BASIX certificate, certificate 1844225S, issued 30 April 2026
BASIX certificate
- Energy score
- 75 (target 68)
- Water score
- 11 (target 0)
- Thermal performance
- Pass
- Materials score
- -35
- Heating load
- 40 MJ/m² a year
- Cooling load
- 35 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 134.2 m²
- Unconditioned floor area
- 19.4 m²
- Site area
- 526 m²
- Roof area
- 288 m²
- Garden area
- 227 m²
- Climate zone
- NatHERS climate zone 46
- Hot water
- Gas instantaneous with a performance of 5 stars
- Solar panels
- 1 kW
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 40.6 m², single glazing 40.6 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1844225S, issued 30 April 2026, from the council's DA documents.
Is this your home? Ask us to remove these details.