North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
43 Keightley Avenue Windradyne NSW 2795
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 64 against 61 for energy and 52 against 40 for water.
Key features
- Windows
- Up to aluminium frames 23.1 m², double glazing 23.1 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Gas instantaneous with a performance of 5 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by John Fitzpatrick Constructions.
BASIX certificate
- Energy score
- 64 (target 61)
- Water score
- 52 (target 40)
- Thermal performance
- Pass
- Materials score
- -49
- Heating load
- 137 MJ/m² a year
- Cooling load
- 4 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 153 m²
- Unconditioned floor area
- 19 m²
- Site area
- 975 m²
- Roof area
- 279 m²
- Climate zone
- NatHERS climate zone 65
- Hot water
- Gas instantaneous with a performance of 5 stars
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 23.1 m², double glazing 23.1 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 3.5 star (cold zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3.5 star (cold zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 3.5 star (cold zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3.5 star (cold zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (foil-foam composite board)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: cavity brick; frame: no frame (no added insulation)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall shared with garage: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1802558S_02, issued 3 July 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.