North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
267 Brilliant Street Bathurst NSW 2795
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 3 kW of solar panels and a 5,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 80 against 61.
Key features
- Windows
- 17 windows and glazed doors: uPVC B DG Argon Fill Low Solar Gain low-E - Clea
- Wall insulation
- R2.7
- Roof and ceiling insulation
- Ceiling R7, roof Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, dark colour
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 80 (target 61)
- Water score
- 40 (target 40)
- Materials score
- -62
- Heating load
- 139 MJ/m² a year
- Cooling load
- 10 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 178 m²
- Unconditioned floor area
- 25 m²
- Site area
- 723 m²
- Roof area
- 150 m²
- Garden area
- 40 m²
- Climate zone
- NatHERS climate zone 65
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 3 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 44.7 m², double glazing 44.7 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (not specified)
- Floor: above habitable rooms or mezzanine, plywood; frame: laminated veneer lumber (LVL) (no added insulation)
- Floor: suspended floor above garage, particle board; frame: laminated veneer lumber (LVL) (rockwool batts, roll or pump-in)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (rockwool batts, roll or pump-in+ foil/sarking)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (foil/sarking)
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (foil/sarking)
- Internal wall shared with garage: plasterboard; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil/sarking.)
Certificate 1804883S_04, issued 29 July 2026, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- BERS Pro v5.2.4 (3.23)
- Rated on
- 19 Jul 2025
- Wall insulation
- R2.7
- Ceiling insulation
- R7
- Floor insulation
- R2.7, R2.5, R2.4, R7, R5
- Living room glazing by direction
- NE 2.4 m², SE 12.9 m², SW 5.5 m², NW 5.7 m²
- All glazing by direction
- NE 12 m², SE 12.9 m², SW 7.7 m², NW 7.3 m²
Roof
- Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, dark colour
Window types
- PVC-006-04 W uPVC B DG Argon Fill Low Solar Gain low-E - Clea: U-value 2, SHGC 0.23
Window schedule
- Living 1, window PVC-006-04 W: 1,800 × 700 mm facing SE
- Living 1, window PVC-006-04 W: 1,800 × 700 mm facing SE
- Living 1, window PVC-006-04 W: 1,800 × 700 mm facing SE
- Living 1, window PVC-006-04 W: 2,100 × 2,100 mm facing SW
- Bedroom 2, window PVC-006-04 W: 1,200 × 1,800 mm facing SW
- Bedroom 3, window PVC-006-04 W: 1,200 × 1,800 mm facing NE
- Unconditioned 1, window PVC-006-04 W: 600 × 2,000 mm facing NE
- Kitchen/Living1, window PVC-006-04 W: 2,000 × 2,400 mm facing SE
- Kitchen/Living1, window PVC-006-04 W: 1,200 × 2,400 mm facing SE
- Kitchen/Living1, window PVC-006-04 W: 600 × 1,800 mm facing SW
- Bedroom 1, window PVC-006-04 W: 2,000 × 600 mm facing NE
- Bedroom 1, window PVC-006-04 W: 1,200 × 2,400 mm facing NE
- Night Time 1, window PVC-006-04 W: 1,200 × 1,800 mm facing NE
- Night Time 2, window PVC-006-04 W: 900 × 1,800 mm facing NW
- Living 2, window PVC-006-04 W: 2,100 × 2,700 mm facing NW
- Living 2, window PVC-006-04 W: 1,200 × 2,000 mm facing NE
- Living 2, window PVC-006-04 W: 600 × 2,400 mm facing SE
Certificate 0012058863, issued 19 July 2025, from the council's DA documents. Verify this certificate
Other certificates for this address
NatHERS certificate, certificate 0013189196, issued 3 August 2026
NatHERS certificate
- Star rating
- 7.2 stars
- Rated with
- BERS Pro v5.2.6 (3.23)
- Rated on
- 03 Aug 2026
- Wall insulation
- R2.7
- Ceiling insulation
- R6
- Floor insulation
- R2.7, R2.5, R1.7, R6, R5
- LED downlights
- 31
- Living room glazing by direction
- NE 2.4 m², SE 11.6 m², SW 5.5 m², NW 5.7 m²
- All glazing by direction
- NE 12 m², SE 11.6 m², SW 7.7 m², NW 7.3 m²
Roof
- Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, dark colour
Window types
- PVC-006-04 W uPVC B DG Argon Fill Low Solar Gain low-E -Clea: U-value 2, SHGC 0.23
Window schedule
- Living 1, window PVC-006-04 W: 1,800 × 700 mm facing SE
- Living 1, window PVC-006-04 W: 1,800 × 700 mm facing SE
- Living 1, window PVC-006-04 W: 2,100 × 2,100 mm facing SW
- Bedroom 2, window PVC-006-04 W: 1,200 × 1,800 mm facing SW
- Bedroom 3, window PVC-006-04 W: 1,200 × 1,800 mm facing NE
- Unconditioned 1, window PVC-006-04 W: 600 × 2,000 mm facing NE
- Kitchen/Living1, window PVC-006-04 W: 2,000 × 2,400 mm facing SE
- Kitchen/Living1, window PVC-006-04 W: 1,200 × 2,400 mm facing SE
- Kitchen/Living1, window PVC-006-04 W: 600 × 1,800 mm facing SW
- Bedroom 1, window PVC-006-04 W: 2,000 × 600 mm facing NE
- Bedroom 1, window PVC-006-04 W: 1,200 × 2,400 mm facing NE
- Night Time 1, window PVC-006-04 W: 1,200 × 1,800 mm facing NE
- Night Time 2, window PVC-006-04 W: 900 × 1,800 mm facing NW
- Living 2, window PVC-006-04 W: 2,100 × 2,700 mm facing NW
- Living 2, window PVC-006-04 W: 1,200 × 2,000 mm facing NE
- Living 2, window PVC-006-04 W: 600 × 2,400 mm facing SE
Certificate 0013189196, issued 3 August 2026, from the council's DA documents. Verify this certificate
BASIX certificate, certificate 1804883S_02, issued 27 November 2025
BASIX certificate
- Energy score
- 79 (target 61)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -60
- Heating load
- 144 MJ/m² a year
- Cooling load
- 11 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 192 m²
- Unconditioned floor area
- 25 m²
- Site area
- 723 m²
- Roof area
- 164 m²
- Garden area
- 40 m²
- Climate zone
- NatHERS climate zone 65
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 3 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 44.7 m², double glazing 44.7 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (not specified)
- Floor: above habitable rooms or mezzanine, plywood; frame: laminated veneer lumber (LVL) (no added insulation)
- Floor: suspended floor above garage, particle board; frame: laminated veneer lumber (LVL) (rockwool batts, roll or pump-in)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (rockwool batts, roll or pump-in+ foil/sarking)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (foil/sarking)
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (foil/sarking)
- Internal wall shared with garage: plasterboard; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil/sarking.)
Certificate 1804883S_02, issued 27 November 2025, from the council's DA documents.