North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
2 Landseer Street Raglan NSW 2795
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7.2 stars out of 10. Its BASIX certificate commits it to 3 kW of solar panels and a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 87 against 61.
Key features
- Windows
- 13 windows and glazed doors: Aluminium B SG High Solar Gain Low-E; Aluminium A SG High Solar Gain Low-E
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R5, roof Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, medium colour
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 87 (target 61)
- Water score
- 40 (target 40)
- Materials score
- -23
- Heating load
- 145 MJ/m² a year
- Cooling load
- 3 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 147 m²
- Unconditioned floor area
- 14.1 m²
- Site area
- 4,605 m²
- Roof area
- 282 m²
- Garden area
- 300 m²
- Climate zone
- NatHERS climate zone 65
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 3 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 19.8 m², timber frames 2.5 m², double glazing 22.3 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (foil-foam composite board)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1796368S_05, issued 24 June 2026, from the council's DA documents.
NatHERS certificate
- Star rating
- 7.2 stars
- Rated with
- BERS Pro v5.2.6 (3.23)
- Rated on
- 09 Feb 2026
- Wall insulation
- R2.5
- Ceiling insulation
- R5
- Floor insulation
- R2.5, R1.5
- Living room glazing by direction
- N 8.4 m²
- All glazing by direction
- N 11.2 m², E 3.2 m², S 6.8 m², W 1.1 m²
Roof
- Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, medium colour
Window types
- ALM-002-03 A Aluminium B SG High Solar Gain Low-E: U-value 5.4, SHGC 0.58
- ALM-001-03 A Aluminium A SG High Solar Gain Low-E: U-value 5.4, SHGC 0.49
Window schedule
- Garage 1, window ALM-002-03 A: 900 × 1,500 mm facing N
- Kitchen/Living1, window ALM-002-03 A: 2,100 × 3,600 mm facing N
- Kitchen/Living1, window ALM-002-03 A: 900 × 900 mm facing N
- Media, window ALM-002-03 A: 600 × 2,400 mm facing N
- Bedroom 1, window ALM-001-03 A: 1,800 × 900 mm facing E
- Bedroom 1, window ALM-001-03 A: 1,800 × 900 mm facing E
- Night Time 1, window ALM-002-03 A: 900 × 600 mm facing S
- Bedroom 2, window ALM-002-03 A: 600 × 2,400 mm facing S
- Bedroom 3, window ALM-002-03 A: 600 × 2,400 mm facing S
- Bedroom 4/study, window ALM-001-03 A: 1,800 × 600 mm facing W
- Unconditioned 1, window ALM-002-03 A: 2,100 × 820 mm facing S
- Unconditioned 2, window ALM-002-03 A: 900 × 600 mm facing S
- Unconditioned 3, window ALM-002-03 A: 900 × 1,200 mm facing S
Certificate 0011931292-01, issued 9 February 2026, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate, certificate 1796368S_04, issued 10 February 2026
BASIX certificate
- Energy score
- 87 (target 61)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -23
- Heating load
- 145 MJ/m² a year
- Cooling load
- 3 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 147 m²
- Unconditioned floor area
- 14.1 m²
- Site area
- 4,605 m²
- Roof area
- 282 m²
- Garden area
- 300 m²
- Climate zone
- NatHERS climate zone 65
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 3 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 19.8 m², timber frames 2.5 m², double glazing 22.3 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (foil-foam composite board)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1796368S_04, issued 10 February 2026, from the council's DA documents.
Is this your home? Ask us to remove these details.