Skip to main content

190A Peel Street Bathurst NSW 2795

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 6.6 kW of solar panels and a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the floor. It beat its BASIX energy and water targets, scoring 90 against 61 for energy and 41 against 40 for water.

Key features

Windows
14 windows and glazed doors: Timber A DG Air Fill Clear-Clear; Type 076 Series Aluminium Sliding Window - Double Glazed; Type 472 Series Aluminium Hinged Door - Double Glazed and 1 more types
Wall insulation
Fibreglass batts or roll
Roof and ceiling insulation
Roof Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 0.00, dark colour
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Brad Schumacher Constructions.

BASIX certificate

Energy score
90 (target 61)
Water score
41 (target 40)
Thermal performance
Pass
Materials score
-32
Heating load
140 MJ/m² a year
Cooling load
16 MJ/m² a year
Bedrooms
3
Conditioned floor area
169.9 m²
Unconditioned floor area
16 m²
Site area
1,328 m²
Roof area
213 m²
Garden area
200 m²
Climate zone
NatHERS climate zone 65
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
6.6 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 36.7 m², timber frames 2.9 m², double glazing 39.6 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (foil-foam composite board)
  • Floor: suspended floor above enclosed subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1833049S, issued 13 February 2026, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
Hero 4.1
Rated on
13 Feb 2026
Floor insulation
R1.70, R2.50, R2.70, R7.00, R6.00
Living room glazing by direction
NE 7.6 m², SE 6.8 m²
All glazing by direction
NE 22.4 m², SE 6.8 m², SW 8.2 m², NW 2.2 m²

Roof

  • Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 0.00, dark colour

Window types

  • TIM-003-01 W Timber A DG Air Fill Clear-Clear: U-value 3, SHGC 0.48
  • GJA-004-033 Type 076 Series Aluminium Sliding Window - Double Glazed: U-value 3.2, SHGC 0.43
  • GJA-083-049 Type 472 Series Aluminium Hinged Door - Double Glazed: U-value 3.5, SHGC 0.47
  • GJA-104-024 Type 048 Series Aluminium Fixed Window - Double Glazed: U-value 2.8, SHGC 0.56

Window schedule

  • BATH, window GJA-004-033: 900 × 1,500 mm facing SW
  • BED 2, window GJA-004-033: 1,200 × 1,800 mm facing NW
  • BED 3, window GJA-004-033: 1,200 × 1,800 mm facing SW
  • ENTRY/STUDY, window GJA-104-024: 2,400 × 600 mm facing SW
  • ENTRY/STUDY, window GJA-083-049: 2,400 × 900 mm facing SW
  • ENTRY/STUDY, window TIM-003-01 W: 2,400 × 1,200 mm facing NE
  • KITCHEN/LIVING/DINING, window GJA-004-033: 2,100 × 1,800 mm facing NE
  • KITCHEN/LIVING/DINING, window GJA-004-033: 2,100 × 1,800 mm facing NE
  • KITCHEN/LIVING/DINING, window GJA-004-033: 1,200 × 1,500 mm facing SE
  • KITCHEN/LIVING/DINING, window GJA-004-033: 2,100 × 2,400 mm facing SE
  • LAUNDRY, window GJA-004-033: 900 × 1,200 mm facing SW
  • MASTER BEDROOM, window GJA-004-033: 2,100 × 2,400 mm facing NE
  • MASTER BEDROOM - ENSUITE, window GJA-004-033: 2,100 × 900 mm facing NE
  • MEDIA, window GJA-004-033: 2,100 × 2,400 mm facing NE

Certificate HR-1VQP4X-02, issued 13 February 2026, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.