North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
96 Old Byron Bay Road Newrybar NSW 2479
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 6.5 stars out of 10. Its BASIX certificate commits it to 5.8 kW of solar panels and a 3,100 litre rainwater tank. It beat its BASIX energy target, scoring 72 against 68.
Key features
- Windows
- Up to aluminium frames 307.3 m², double glazing 307.3 m²
- Wall insulation
- No added insulation; Polystyrene; Not specified
- Roof and ceiling insulation
- Ceiling: polystyrene; roof: none; Ceiling: polystyrene; roof: foil backed blanket
- Hot water
- Electric heat pump
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 72 (target 68)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 11 MJ/m² a year
- Cooling load
- 53 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 484 m²
- Site area
- 192,055 m²
- Roof area
- 950 m²
- Garden area
- 394 m²
- Climate zone
- NatHERS climate zone 10
- Hot water
- Electric heat pump
- Solar panels
- 5.8 kW
- Rainwater tank
- 3,100 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 307.3 m², double glazing 307.3 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER > 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER > 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER > 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER > 4.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - untreated softwood (no added insulation)
- External wall: brick veneer; frame: timber - untreated softwood (polystyrene)
- External wall: brick veneer; frame: timber - untreated softwood (not specified)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - untreated softwood (polystyrene)
- External garage wall: brick veneer; frame: timber - untreated softwood (not specified)
- Internal wall: 75 mm AAC panel; frame: timber - untreated softwood (not specified)
- Ceiling and roof: flat ceiling / pitched roof, concrete - plasterboard internal, timber - untreated softwood (ceiling: polystyrene; roof: none.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - untreated softwood (ceiling: polystyrene; roof: foil backed blanket.)
Certificate 1362768S_03, issued 2 June 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 6.5 stars
- Rated with
- BERS Pro v5.1.7 (3.22)
- Rated on
- 19 Sep 2024
Certificate 0009138010, issued 19 September 2024, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate (multi dwelling), certificate 1765291M, issued 19 September 2024
BASIX certificate (multi dwelling)
This BASIX certificate covers more than one dwelling on the lot, such as a house and a granny flat, so some of its numbers are for the whole development.
- Energy score
- 73 (target 68)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Site area
- 192,055 m²
- Roof area
- 1,804 m²
- Climate zone
- NatHERS climate zone 10
- Clothes line
- Yes
Certificate 1765291M, issued 19 September 2024, from the council's DA documents.