North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
727 Hinterland Way Newrybar NSW 2479
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7.3 stars out of 10. Its BASIX certificate commits it to 0.3 kW of solar panels and a 5,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 51 against 40.
Key features
- Windows
- 56 windows and glazed doors: Timber B SG Clear; Timber A SG Clear
- Wall insulation
- R1.7, R2.7
- Roof and ceiling insulation
- Ceiling R3.5, R4.5, roof Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.4, medium colour
- Hot water
- Electric boosted solar with a performance of 31 to 35 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom); Wood heater (living area)
BASIX certificate
- Energy score
- 68 (target 68)
- Water score
- 51 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 7 MJ/m² a year
- Cooling load
- 24 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 448.5 m²
- Unconditioned floor area
- 33.2 m²
- Site area
- 250,000 m²
- Roof area
- 720 m²
- Garden area
- 100 m²
- Climate zone
- NatHERS climate zone 10
- Hot water
- Electric boosted solar with a performance of 31 to 35 STCs or better
- Solar panels
- 0.3 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Maximum glazing
- timber frames 110.6 m², single glazing 110.6 m²
Heating
- Living area: wood heater; Energy rating: n/a
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 star (hot zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 6 star (hot zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 star (hot zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- External wall: cavity brick; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: mudbrick or rammed earth; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: cavity brick wall; frame: no frame (polystyrene)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1791651S, issued 13 April 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7.3 stars
- Rated with
- BERS Pro v4.4.1.5 (3.21)
- Rated on
- 13 Apr 2025
- Wall insulation
- R1.7, R2.7
- Ceiling insulation
- R3.5, R4.5
- Floor insulation
- R1.5
- LED downlights
- 84
- Living room glazing by direction
- N 24 m², E 9.9 m², S 8.6 m², W 5.3 m²
- All glazing by direction
- N 39.1 m², E 36.8 m², S 15.3 m², W 19.4 m²
Roof
- Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.4, medium colour
- Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.5, medium colour
Window types
- TIM-002-01 W Timber B SG Clear: U-value 5.4, SHGC 0.63
- TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
Window schedule
- Bedroom 1, window TIM-002-01 W: 700 × 500 mm facing W
- Bedroom 1, window TIM-002-01 W: 700 × 500 mm facing W
- Bedroom 1, window TIM-002-01 W: 700 × 500 mm facing W
- Bedroom 1, window TIM-002-01 W: 1,950 × 3,000 mm facing N
- Ensuite Bed 1, window TIM-002-01 W: 700 × 500 mm facing W
- Ensuite Bed 1, window TIM-001-01 W: 1,800 × 1,500 mm facing W
- WIR Bed 1, window TIM-002-01 W: 1,500 × 750 mm facing S
- WIR Bed 1, window TIM-002-01 W: 2,100 × 750 mm facing W
- Pantry, window TIM-001-01 W: 1,500 × 1,000 mm facing N
- Kitchen/Living, window TIM-001-01 W: 1,800 × 1,500 mm facing E
- Kitchen/Living, window TIM-002-01 W: 2,400 × 750 mm facing E
- Kitchen/Living, window TIM-002-01 W: 2,400 × 750 mm facing E
- Kitchen/Living, window TIM-002-01 W: 2,400 × 1,500 mm facing E
- Kitchen/Living, window TIM-002-01 W: 2,400 × 750 mm facing S
- Kitchen/Living, window TIM-002-01 W: 2,400 × 750 mm facing S
- Kitchen/Living, window TIM-001-01 W: 2,400 × 1,500 mm facing S
- Kitchen/Living, window TIM-002-01 W: 1,500 × 900 mm facing S
- Kitchen/Living, window TIM-002-01 W: 2,400 × 750 mm facing N
- Kitchen/Living, window TIM-002-01 W: 2,400 × 1,500 mm facing N
- Kitchen/Living, window TIM-002-01 W: 2,400 × 1,500 mm facing N
- Kitchen/Living, window TIM-002-01 W: 2,400 × 750 mm facing N
- Kitchen/Living, window TIM-002-01 W: 2,400 × 750 mm facing N
- Kitchen/Living, window TIM-002-01 W: 2,400 × 750 mm facing N
- Kitchen/Living, window TIM-002-01 W: 1,800 × 1,500 mm facing W
- Kitchen/Living, window TIM-002-01 W: 2,400 × 750 mm facing N
- Kitchen/Living, window TIM-002-01 W: 2,400 × 750 mm facing N
- Kitchen/Living, window TIM-002-01 W: 2,400 × 1,500 mm facing N
- Kitchen/Living, window TIM-002-01 W: 500 × 3,000 mm facing N
- Media/Library, window TIM-002-01 W: 1,500 × 3,000 mm facing E
- Bedroom 2, window TIM-002-01 W: 2,400 × 750 mm facing E
- Bedroom 2, window TIM-002-01 W: 2,400 × 750 mm facing E
- Bedroom 2, window TIM-001-01 W: 2,400 × 1,500 mm facing E
- Bedroom 2, window TIM-002-01 W: 1,800 × 900 mm facing S
- Bedroom 2, window TIM-002-01 W: 1,800 × 900 mm facing S
- Ensuite Bed 2, window TIM-002-01 W: 1,500 × 900 mm facing E
- Bedroom 3, window TIM-002-01 W: 2,400 × 780 mm facing E
- Bedroom 3, window TIM-002-01 W: 2,400 × 780 mm facing E
- Bedroom 3, window TIM-001-01 W: 2,400 × 1,500 mm facing E
- Ensuite Bed 2, window TIM-002-01 W: 1,500 × 900 mm facing E
- Office, window TIM-002-01 W: 1,800 × 900 mm facing S
- Gallery/Enrty, window TIM-002-01 W: 1,500 × 500 mm facing N
- Gallery/Enrty, window TIM-002-01 W: 1,500 × 500 mm facing W
- Gallery/Enrty, window TIM-002-01 W: 1,500 × 500 mm facing W
- Gallery/Enrty, window TIM-002-01 W: 2,400 × 1,500 mm facing W
- Laundry, window TIM-001-01 W: 2,100 × 1,240 mm facing E
- Laundry, window TIM-002-01 W: 1,500 × 900 mm facing N
- Stairway, window TIM-001-01 W: 2,100 × 1,240 mm facing E
- Stairway, window TIM-002-01 W: 1,500 × 500 mm facing S
- Bedroom 4, window TIM-001-01 W: 2,100 × 1,240 mm facing W
- Bedroom 4, window TIM-002-01 W: 1,500 × 900 mm facing N
- Bedroom 4, window TIM-002-01 W: 1,500 × 900 mm facing N
- Bathroom, window TIM-002-01 W: 1,200 × 600 mm facing W
- Bedroom 5, window TIM-002-01 W: 1,000 × 900 mm facing N
- Bathroom L1, window TIM-002-01 W: 1,000 × 2,000 mm facing N
- Rumpus L1, window TIM-002-01 W: 2,100 × 1,240 mm facing W
- Rumpus L1, window TIM-002-01 W: 1,000 × 900 mm facing N
Certificate 0011861275, issued 13 April 2025, from the council's DA documents.
Other certificates for this address
BASIX certificate (alterations and additions), certificate A1790852, issued 8 April 2025
BASIX certificate (alterations and additions)
This BASIX certificate is for alterations and additions, such as an extension or a pool, rather than a whole new house.
- LED lighting
- Yes
Certificate A1790852, issued 8 April 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.