North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
195 Cumbalum Road Cumbalum NSW 2478
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 6.6 stars out of 10. Its BASIX certificate commits it to 3 kW of solar panels and a 20,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 76 against 68 for energy and 55 against 40 for water.
Key features
- Windows
- 54 windows and glazed doors: Altair Louvre Comp in a timber frame; Cedar Awning Window; Cedar Sliding Door - Single Glazed and 3 more types
- Wall insulation
- Fibreglass batts or roll+ foil/sarking; Polyurethane
- Roof and ceiling insulation
- Roof Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 1.30, light colour
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom); Wood heater (living area)
BASIX certificate
- Energy score
- 76 (target 68)
- Water score
- 55 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 13 MJ/m² a year
- Cooling load
- 36 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 578.6 m²
- Unconditioned floor area
- 15.7 m²
- Site area
- 444,000 m²
- Roof area
- 518 m²
- Garden area
- 200 m²
- Climate zone
- NatHERS climate zone 10
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Solar panels
- 3 kW
- Rainwater tank
- 20,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 180.5 m², single glazing 180.5 m²
Heating
- Living area: wood heater; Energy rating: n/a
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 4.5 star (hot zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 4.5 star (hot zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 4.5 star (hot zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (not specified)
- Floor: above habitable rooms or mezzanine, particle board; frame: laminated veneer lumber (LVL) (not specified)
- Floor: suspended floor above garage, particle board; frame: laminated veneer lumber (LVL) (not specified)
- Garage floor: concrete slab on ground (not specified)
- External wall: framed (metal clad); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (metal clad); frame: light steel frame (polyurethane)
- External garage wall: framed (metal clad); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall shared with garage: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (not specified)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1780033S_02, issued 2 December 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 6.6 stars
- Rated with
- Hero 4.1
- Rated on
- 15 Jan 2025
- Living room glazing by direction
- NE 21.9 m², SE 49.5 m², SW 17.2 m², NW 10 m²
- All glazing by direction
- NE 43.8 m², SE 87.4 m², SW 19.6 m², NW 29.8 m²
Roof
- Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 1.30, light colour
- FLAT-01: Flat Framed / Skillion Metal Roof & Flat PB Ceiling 1.30, light colour
- FLAT-02: Flat Framed / Skillion Metal Roof & Cathedral PB Ceiling (11°-33°) 1.30, light colour
Window types
- BRZ-005-001 Altair Louvre Comp in a timber frame: U-value 4.9, SHGC 0.58
- STG-017-003 Cedar Awning Window: U-value 4.72, SHGC 0.58
- STG-021-002 Cedar Sliding Door - Single Glazed: U-value 4.47, SHGC 0.55
- STG-023-003 Cedar Sliding Window - SG: U-value 4.66, SHGC 0.56
- STG-038-003 Cedar Hinged Door: U-value 2, SHGC 0.39
- STG-083-003 Cedar Fixed Window - Single Glazed: U-value 3.48, SHGC 0.62
Window schedule
- Basement Foyer/Entrance, window BRZ-005-001: 1,500 × 1,000 mm facing NE
- Basement Foyer/Entrance, window STG-083-003: 1,500 × 2,000 mm facing NE
- Bathroom 01, window STG-083-003: 1,500 × 1,339 mm facing NE
- Bedroom 01, window BRZ-005-001: 1,900 × 1,068 mm facing SE
- Bedroom 01, window STG-023-003: 1,900 × 3,670 mm facing SE
- Bedroom 02, window BRZ-005-001: 1,900 × 1,074 mm facing SE
- Bedroom 02, window STG-023-003: 1,900 × 3,673 mm facing SE
- Bedroom 03, window STG-023-003: 1,900 × 3,508 mm facing SE
- Bedroom 03, window BRZ-005-001: 1,900 × 1,099 mm facing SE
- Family, window STG-023-003: 1,900 × 3,059 mm facing SE
- Family, window BRZ-005-001: 1,900 × 1,369 mm facing SE
- Family, window STG-023-003: 1,900 × 3,177 mm facing SE
- Family, window BRZ-005-001: 1,900 × 1,382 mm facing SE
- Family, window BRZ-005-001: 1,000 × 2,000 mm facing NW
- Family, window BRZ-005-001: 1,000 × 1,998 mm facing NW
- Foyer, window STG-038-003: 2,400 × 975 mm facing NW
- Foyer, window STG-083-003: 2,400 × 2,925 mm facing NW
- Foyer, window STG-083-003: 900 × 975 mm facing SE
- Foyer, window BRZ-005-001: 900 × 975 mm facing SE
- Foyer, window STG-038-003: 900 × 1,950 mm facing SE
- Garage, window STG-038-003: 2,750 × 1,000 mm facing NE
- Garage, window BRZ-005-001: 1,500 × 1,000 mm facing NE
- Garage, window BRZ-005-001: 1,500 × 1,000 mm facing NE
- Garage, window STG-083-003: 1,500 × 2,125 mm facing NE
- Guest Bedroom, window STG-083-003: 1,500 × 2,000 mm facing NE
- Guest Bedroom, window BRZ-005-001: 1,500 × 1,000 mm facing NE
- Hallway 01, window STG-083-003: 1,000 × 1,000 mm facing NW
- Kitchen/Living/Dining, window STG-083-003: 2,450 × 5,000 mm facing SW
- Kitchen/Living/Dining, window BRZ-005-001: 2,450 × 1,000 mm facing SW
- Kitchen/Living/Dining, window STG-083-003: 2,450 × 1,000 mm facing SW
- Kitchen/Living/Dining, window STG-083-003: 1,500 × 4,000 mm facing NW
- Kitchen/Living/Dining, window STG-083-003: 1,500 × 1,500 mm facing NE
- Kitchen/Living/Dining, window STG-083-003: 1,500 × 2,041 mm facing NE
- Kitchen/Living/Dining, window STG-083-003: 1,500 × 2,060 mm facing NE
- Kitchen/Living/Dining, window BRZ-005-001: 1,500 × 900 mm facing NE
- Kitchen/Living/Dining, window STG-083-003: 1,500 × 2,100 mm facing NE
- Kitchen/Living/Dining, window BRZ-005-001: 1,500 × 900 mm facing NE
- Kitchen/Living/Dining, window BRZ-005-001: 1,500 × 1,000 mm facing NE
- Kitchen/Living/Dining, window BRZ-005-001: 1,500 × 1,000 mm facing NE
- Kitchen/Living/Dining, window BRZ-005-001: 1,500 × 1,000 mm facing NE
- Kitchen/Living/Dining, window STG-083-003: 1,500 × 2,125 mm facing NE
- Kitchen/Living/Dining, window STG-021-002: 2,700 × 6,000 mm facing SE
- Kitchen/Living/Dining, window STG-083-003: 2,700 × 6,000 mm facing SE
- Laundry, window BRZ-005-001: 1,000 × 1,000 mm facing NW
- Master Bedroom, window BRZ-005-001: 1,900 × 1,188 mm facing SE
- Master Bedroom, window STG-023-003: 1,900 × 2,819 mm facing SE
- Master Bedroom, window BRZ-005-001: 2,400 × 1,000 mm facing SW
- Master Bedroom, window STG-017-003: 1,800 × 1,000 mm facing NW
- Master Ensuite, window BRZ-005-001: 1,830 × 1,990 mm facing NW
- Powder, window BRZ-005-001: 1,000 × 1,000 mm facing NW
- Shower, window BRZ-005-001: 1,000 × 1,000 mm facing NW
- WC, window STG-083-003: 1,500 × 423 mm facing NE
- WC, window BRZ-005-001: 1,500 × 846 mm facing NE
- WC 02, window BRZ-005-001: 1,000 × 1,000 mm facing NW
Certificate HR-RM5P5X-01, issued 15 January 2025, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate, certificate 1780033S, issued 15 January 2025
BASIX certificate
- Energy score
- 76 (target 68)
- Water score
- 55 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 9 MJ/m² a year
- Cooling load
- 38 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 598 m²
- Unconditioned floor area
- 17.1 m²
- Site area
- 444,000 m²
- Roof area
- 518 m²
- Garden area
- 200 m²
- Climate zone
- NatHERS climate zone 10
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Solar panels
- 3 kW
- Rainwater tank
- 20,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 180.5 m², single glazing 180.5 m²
Heating
- Living area: wood heater; Energy rating: n/a
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 4.5 star (hot zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 4.5 star (hot zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 4.5 star (hot zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (not specified)
- Floor: above habitable rooms or mezzanine, particle board; frame: laminated veneer lumber (LVL) (not specified)
- Floor: suspended floor above garage, particle board; frame: laminated veneer lumber (LVL) (not specified)
- Garage floor: concrete slab on ground (not specified)
- External wall: framed (metal clad); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (metal clad); frame: light steel frame (polyurethane)
- External garage wall: framed (metal clad); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall shared with garage: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (not specified)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1780033S, issued 15 January 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.