Skip to main content

1 Salt Air Circuit Lennox Head NSW 2478

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 5.8 stars out of 10. Its BASIX certificate commits it to 2 kW of solar panels. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 78 against 68 for energy and 50 against 40 for water.

Key features

Windows
11 windows and glazed doors: Aluminium Sliding Window SG 6.38CPNtl; Aluminium Sliding Door SG 6.38CPNtl; Aluminium Awning Window SG 6.38CPNtl
Wall insulation
R2
Roof and ceiling insulation
Ceiling R2.5, roof Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
Hot water
Electric storage
Air conditioning and heating
1-phase airconditioning, non ducted (living area and bedroom)

BASIX certificate

Energy score
78 (target 68)
Water score
50 (target 40)
Thermal performance
Pass
Materials score
24
Heating load
12 MJ/m² a year
Cooling load
44 MJ/m² a year
Bedrooms
3
Conditioned floor area
152.1 m²
Site area
292 m²
Roof area
114 m²
Garden area
120 m²
Climate zone
NatHERS climate zone 10
Hot water
Electric storage
Solar panels
2 kW
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Maximum glazing
aluminium frames 44 m², single glazing 44 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (no added insulation)
  • External wall: external insulated façade system (EIFS); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1762714S, issued 3 September 2024, from the council's DA documents.

NatHERS certificate

Star rating
5.8 stars
Rated with
BERS Pro v5.2.2 (3.23)
Rated on
30 Aug 2024
Wall insulation
R2
Ceiling insulation
R2.5
Floor insulation
R2, R1.5, R2.5
LED downlights
30
Living room glazing by direction
NE 1.9 m², NW 14.4 m²
All glazing by direction
NE 6.2 m², SE 23 m², NW 14.4 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour

Window types

  • GJA-035-330 Aluminium Sliding Window SG 6.38CPNtl: U-value 5, SHGC 0.41
  • GJA-070-042 Aluminium Sliding Door SG 6.38CPNtl: U-value 4.4, SHGC 0.44
  • GJA-001-032 Aluminium Awning Window SG 6.38CPNtl: U-value 4.8, SHGC 0.39

Window schedule

  • MPU, window GJA-035-330: 600 × 2,400 mm facing NE
  • MPU, window GJA-070-042: 2,400 × 2,700 mm facing SE
  • Bed 3, window GJA-070-042: 2,400 × 2,700 mm facing SE
  • Bed 1, window GJA-035-330: 600 × 2,400 mm facing NE
  • Bed 1, window GJA-070-042: 2,400 × 1,800 mm facing SE
  • Bed 2, window GJA-070-042: 2,400 × 2,400 mm facing SE
  • Entry/Hall, window GJA-001-032: 2,400 × 600 mm facing NE
  • Kitchen/Living, window GJA-070-042: 2,400 × 2,400 mm facing NW
  • Kitchen/Living, window GJA-070-042: 2,400 × 3,600 mm facing NW
  • Kitchen/Living, window GJA-001-032: 2,400 × 400 mm facing NE
  • Kitchen/Living, window GJA-001-032: 2,400 × 400 mm facing NE

Certificate 0009728601-01, issued 30 August 2024, from the council's DA documents.

Other certificates for this address

BASIX certificate, certificate 1762713S, issued 3 September 2024

BASIX certificate

Energy score
79 (target 68)
Water score
50 (target 40)
Thermal performance
Pass
Materials score
26
Heating load
11 MJ/m² a year
Cooling load
45 MJ/m² a year
Bedrooms
3
Conditioned floor area
130.9 m²
Site area
188 m²
Roof area
112 m²
Garden area
120 m²
Climate zone
NatHERS climate zone 10
Hot water
Electric storage
Solar panels
2 kW
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Maximum glazing
aluminium frames 40 m², single glazing 40 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (no added insulation)
  • External wall: external insulated façade system (EIFS); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1762713S, issued 3 September 2024, from the council's DA documents.

BASIX certificate, certificate 1762712S, issued 3 September 2024

BASIX certificate

Energy score
79 (target 68)
Water score
50 (target 40)
Thermal performance
Pass
Materials score
26
Heating load
13 MJ/m² a year
Cooling load
42 MJ/m² a year
Bedrooms
3
Conditioned floor area
130.9 m²
Site area
188 m²
Roof area
112 m²
Garden area
120 m²
Climate zone
NatHERS climate zone 10
Hot water
Electric storage
Solar panels
2 kW
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Maximum glazing
aluminium frames 40 m², single glazing 40 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (no added insulation)
  • External wall: external insulated façade system (EIFS); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1762712S, issued 3 September 2024, from the council's DA documents.

BASIX certificate, certificate 1762707S, issued 3 September 2024

BASIX certificate

Energy score
79 (target 68)
Water score
50 (target 40)
Thermal performance
Pass
Materials score
26
Heating load
11 MJ/m² a year
Cooling load
45 MJ/m² a year
Bedrooms
3
Conditioned floor area
130.9 m²
Site area
188 m²
Roof area
112 m²
Garden area
120 m²
Climate zone
NatHERS climate zone 10
Hot water
Electric storage
Solar panels
2 kW
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Maximum glazing
aluminium frames 40 m², single glazing 40 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (no added insulation)
  • External wall: external insulated façade system (EIFS); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1762707S, issued 3 September 2024, from the council's DA documents.

BASIX certificate, certificate 1762698S, issued 3 September 2024

BASIX certificate

Energy score
79 (target 68)
Water score
50 (target 40)
Thermal performance
Pass
Materials score
26
Heating load
13 MJ/m² a year
Cooling load
42 MJ/m² a year
Bedrooms
3
Conditioned floor area
130.9 m²
Site area
188 m²
Roof area
112 m²
Garden area
120 m²
Climate zone
NatHERS climate zone 10
Hot water
Electric storage
Solar panels
2 kW
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Maximum glazing
aluminium frames 40 m², single glazing 40 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (no added insulation)
  • External wall: external insulated façade system (EIFS); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1762698S, issued 3 September 2024, from the council's DA documents.

BASIX certificate, certificate 1762386S, issued 30 August 2024

BASIX certificate

Energy score
77 (target 68)
Water score
49 (target 40)
Thermal performance
Pass
Materials score
25
Heating load
13 MJ/m² a year
Cooling load
50 MJ/m² a year
Bedrooms
3
Conditioned floor area
152.1 m²
Site area
283 m²
Roof area
120 m²
Garden area
150 m²
Climate zone
NatHERS climate zone 10
Hot water
Electric storage
Solar panels
2 kW
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Maximum glazing
aluminium frames 43 m², single glazing 37 m², double glazing 6 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (polystyrene)
  • Floor: suspended floor above enclosed subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (no added insulation)
  • External wall: external insulated façade system (EIFS); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1762386S, issued 30 August 2024, from the council's DA documents.

NatHERS certificate, certificate 0009728783, issued 30 August 2024

NatHERS certificate

Star rating
5.2 stars
Rated with
BERS Pro v5.2.2 (3.23)
Rated on
30 Aug 2024
Wall insulation
R2.5, R2
Ceiling insulation
R3, R2.5
Floor insulation
R2.5, R2, R1.5
LED downlights
30
Living room glazing by direction
SW 1.9 m², NW 14.4 m²
All glazing by direction
SE 22.3 m², SW 6.1 m², NW 14.4 m²

Roof

  • Waterproofing Membrane No Insulation, Only an Air Gap, medium colour
  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour

Window types

  • GJA-071-021 Aluminium Sliding Door DG 6EA/8/4Clr: U-value 3.5, SHGC 0.53
  • GJA-035-330 Aluminium Sliding Window SG 6.38CPNtl: U-value 5, SHGC 0.41
  • GJA-070-042 Aluminium Sliding Door SG 6.38CPNtl: U-value 4.4, SHGC 0.44
  • GJA-001-032 Aluminium Awning Window SG 6.38CPNtl: U-value 4.8, SHGC 0.39

Window schedule

  • MPU, window GJA-071-021: 2,400 × 2,400 mm facing SE
  • MPU, window GJA-035-330: 600 × 2,100 mm facing SW
  • Bed 3, window GJA-070-042: 2,400 × 2,700 mm facing SE
  • Bed 1, window GJA-070-042: 2,400 × 1,800 mm facing SE
  • Bed 1, window GJA-035-330: 600 × 2,400 mm facing SW
  • Bed 2, window GJA-070-042: 2,400 × 2,400 mm facing SE
  • Entry/Hall, window GJA-001-032: 2,400 × 600 mm facing SW
  • Kitchen/Living, window GJA-001-032: 2,400 × 400 mm facing SW
  • Kitchen/Living, window GJA-001-032: 2,400 × 400 mm facing SW
  • Kitchen/Living, window GJA-070-042: 2,400 × 2,400 mm facing NW
  • Kitchen/Living, window GJA-070-042: 2,400 × 3,600 mm facing NW

Certificate 0009728783, issued 30 August 2024, from the council's DA documents.

NatHERS certificate, certificate 0009728718, issued 30 August 2024

NatHERS certificate

Star rating
5.8 stars
Rated with
BERS Pro v5.2.2 (3.23)
Rated on
30 Aug 2024
Wall insulation
R2
Ceiling insulation
R2.5
Floor insulation
R2, R1.5, R2.5
LED downlights
28
Living room glazing by direction
N 6.6 m², SE 12.2 m²
All glazing by direction
N 6.6 m², SE 26.6 m², NW 13.7 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour

Window types

  • GJA-070-042 Aluminium Sliding Door SG 6.38CPNtl: U-value 4.4, SHGC 0.44
  • GJA-082-034 Aluminium Hinged Door SG 6.38CPNtl: U-value 4.6, SHGC 0.39
  • A&L-001-004 Aluminium Awning Window SG 4Clr: U-value 5.8, SHGC 0.65

Window schedule

  • MPU, window GJA-070-042: 2,400 × 2,700 mm facing SE
  • Bed 3, window GJA-070-042: 2,400 × 2,400 mm facing SE
  • Grd Stairs, window GJA-082-034: 2,400 × 900 mm facing SE
  • Kitchen/Living, window GJA-070-042: 2,400 × 2,700 mm facing SE
  • Kitchen/Living, window GJA-070-042: 2,400 × 2,400 mm facing SE
  • Kitchen/Living, window A&L-001-004: 900 × 7,300 mm facing N
  • Stairs/Hall, window GJA-082-034: 2,400 × 900 mm facing NW
  • Bed 2, window GJA-070-042: 2,400 × 2,400 mm facing NW
  • Bed 1, window GJA-070-042: 2,400 × 2,400 mm facing NW

Certificate 0009728718, issued 30 August 2024, from the council's DA documents.

NatHERS certificate, certificate 0009728692-01, issued 30 August 2024

NatHERS certificate

Star rating
5.8 stars
Rated with
BERS Pro v5.2.2 (3.23)
Rated on
30 Aug 2024
Wall insulation
R2
Ceiling insulation
R2.5
Floor insulation
R2, R1.5, R2.5
LED downlights
28
Living room glazing by direction
N 6.6 m², SE 12.2 m²
All glazing by direction
N 6.6 m², SE 26.6 m², NW 13.7 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour

Window types

  • GJA-070-042 Aluminium Sliding Door SG 6.38CPNtl: U-value 4.4, SHGC 0.44
  • GJA-082-034 Aluminium Hinged Door SG 6.38CPNtl: U-value 4.6, SHGC 0.39
  • A&L-001-004 Aluminium Awning Window SG 4Clr: U-value 5.8, SHGC 0.65

Window schedule

  • MPU, window GJA-070-042: 2,400 × 2,700 mm facing SE
  • Bed 3, window GJA-070-042: 2,400 × 2,400 mm facing SE
  • Grd Stairs, window GJA-082-034: 2,400 × 900 mm facing SE
  • Kitchen/Living, window GJA-070-042: 2,400 × 2,400 mm facing SE
  • Kitchen/Living, window GJA-070-042: 2,400 × 2,700 mm facing SE
  • Kitchen/Living, window A&L-001-004: 900 × 7,300 mm facing N
  • Stairs/Hall, window GJA-082-034: 2,400 × 900 mm facing NW
  • Bed 2, window GJA-070-042: 2,400 × 2,400 mm facing NW
  • Bed 1, window GJA-070-042: 2,400 × 2,400 mm facing NW

Certificate 0009728692-01, issued 30 August 2024, from the council's DA documents.

NatHERS certificate, certificate 0009728676-01, issued 30 August 2024

NatHERS certificate

Star rating
5.8 stars
Rated with
BERS Pro v5.2.2 (3.23)
Rated on
30 Aug 2024
Wall insulation
R2
Ceiling insulation
R2.5
Floor insulation
R2, R1.5, R2.5
LED downlights
28
Living room glazing by direction
N 6.6 m², SE 12.2 m²
All glazing by direction
N 6.6 m², SE 26.6 m², NW 13.7 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour

Window types

  • GJA-070-042 Aluminium Sliding Door SG 6.38CPNtl: U-value 4.4, SHGC 0.44
  • GJA-082-034 Aluminium Hinged Door SG 6.38CPNtl: U-value 4.6, SHGC 0.39
  • A&L-001-004 Aluminium Awning Window SG 4Clr: U-value 5.8, SHGC 0.65

Window schedule

  • MPU, window GJA-070-042: 2,400 × 2,700 mm facing SE
  • Bed 3, window GJA-070-042: 2,400 × 2,400 mm facing SE
  • Grd Stairs, window GJA-082-034: 2,400 × 900 mm facing SE
  • Kitchen/Living, window GJA-070-042: 2,400 × 2,700 mm facing SE
  • Kitchen/Living, window GJA-070-042: 2,400 × 2,400 mm facing SE
  • Kitchen/Living, window A&L-001-004: 900 × 7,300 mm facing N
  • Stairs/Hall, window GJA-082-034: 2,400 × 900 mm facing NW
  • Bed 2, window GJA-070-042: 2,400 × 2,400 mm facing NW
  • Bed 1, window GJA-070-042: 2,400 × 2,400 mm facing NW

Certificate 0009728676-01, issued 30 August 2024, from the council's DA documents.

NatHERS certificate, certificate 0009728650-01, issued 30 August 2024

NatHERS certificate

Star rating
5.8 stars
Rated with
BERS Pro v5.2.2 (3.23)
Rated on
30 Aug 2024
Wall insulation
R2
Ceiling insulation
R2.5
Floor insulation
R2, R1.5, R2.5
LED downlights
28
Living room glazing by direction
N 6.6 m², SE 12.2 m²
All glazing by direction
N 6.6 m², SE 26.6 m², NW 13.7 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour

Window types

  • GJA-070-042 Aluminium Sliding Door SG 6.38CPNtl: U-value 4.4, SHGC 0.44
  • GJA-082-034 Aluminium Hinged Door SG 6.38CPNtl: U-value 4.6, SHGC 0.39
  • A&L-001-004 Aluminium Awning Window SG 4Clr: U-value 5.8, SHGC 0.65

Window schedule

  • MPU, window GJA-070-042: 2,400 × 2,700 mm facing SE
  • Bed 3, window GJA-070-042: 2,400 × 2,400 mm facing SE
  • Grd Stairs, window GJA-082-034: 2,400 × 900 mm facing SE
  • Kitchen/Living, window GJA-070-042: 2,400 × 2,400 mm facing SE
  • Kitchen/Living, window GJA-070-042: 2,400 × 2,700 mm facing SE
  • Kitchen/Living, window A&L-001-004: 900 × 7,300 mm facing N
  • Stairs/Hall, window GJA-082-034: 2,400 × 900 mm facing NW
  • Bed 2, window GJA-070-042: 2,400 × 2,400 mm facing NW
  • Bed 1, window GJA-070-042: 2,400 × 2,400 mm facing NW

Certificate 0009728650-01, issued 30 August 2024, from the council's DA documents.

Is this your home? Ask us to remove these details.